1. Receipt and condition assessment

Inbound packages are logged on arrival. Before anything is accessioned we record the condition of the shipment: packaging integrity, whether temperature control was maintained where the submission required it, seal condition, and whether the labelling matches the submitted order.

Where a sample arrives in a condition that could affect the result, we record the deviation and contact the client before proceeding. Consistent with ISO/IEC 17025 clause 7.4, if the client asks us to proceed anyway, we proceed and the certificate carries a statement of the deviation. We do not quietly test a compromised sample and print a clean-looking certificate.

2. Accessioning

At accessioning the sample receives a unique accession number in the form AVR-YY-NNNNNN. From that moment the sample has an identity independent of any label the client applied to it, and every subsequent event is written to an append-only custody log with an actor and a timestamp.

The custody log cannot be edited or deleted. Clients see their own custody record in the portal, in the same form the laboratory sees it.

3. Aliquoting and storage

MaterialConditionPurpose
Working aliquotPrepared for analysis on the day of the runConsumed by testing
Retained aliquotSealed, −20 °C, access-controlled storageRe-test, dispute resolution, stability timepoints
Original containerRetained with remaining contents where any remainIdentity and labelling questions

4. Retention period

Retained material is held for 90 days from accession. The retention date is set automatically at accessioning and is visible to the client in the portal from that moment, so nobody has to ask us when the window closes.

Where a sample is enrolled in the stability programme, retention extends to cover the full schedule of timepoints plus 30 days beyond the final one.

Records, as distinct from material, are retained far longer. Certificates, results, custody events and audit entries are retained permanently and are never deleted, as described in the publication policy.

5. Re-testing from retained material

Any client may request a re-test on the retained aliquot within the retention window. This is the only clean way to settle a disagreement about a result, because it removes the variable that otherwise dominates every such argument, which is whether the second sample was the same material as the first.

A re-test issues its own certificate referencing the original accession. Where a re-test contradicts the original, both stay on record and the original is marked superseded. Neither disappears.

6. Return and disposal

  • A client may request return of remaining material at any point during the retention window, at the client's cost and risk in transit. Return closes the retention window and ends our ability to re-test.
  • Material not returned is disposed of after the retention window through a licensed waste contractor, under the disposal route appropriate to the material.
  • Disposal is logged against the accession. The custody record therefore has an end as well as a beginning.
  • Material that is discovered to be a controlled substance is handled under the applicable federal and state requirements, which may include notification. This is described in the terms of service and is not a discretionary matter.

7. Access control

Retained material is held in access-controlled storage. Physical access is limited to laboratory personnel with a role that requires it, and every state change to a sample is attributable to an individual actor in the custody log. Commercial staff have no path to laboratory material and no release authority in the system.

8. Client-supplied information

Product name, lot number and labelled content are supplied by the client. We report them as supplied and identify them on the certificate as client-supplied. We verify what we measure. We do not independently verify a lot number, and we do not imply that we have.